ORP10-Oxidation Reduction Potential (ORP) Transmitter, RS485, Modbus
View:5787 Category:Measurements Category:ORP Category:Products
Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
Resources | |
User Manual | UM-ORP10 Oxidation Reduction Potential Transmitter |
Software | SensorOneSet-EN |
Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
?
■ ORP measurement
■ Output Interface with RS485, Voltage, Current
■ High accuracy with excellent stability
■ Reverse power protection and Built-in TVS/ESD protection
Specifications | |||
Output Interface | Analog Voltage 0-2V
(Output resistance ~0ohm) |
Analog Current 4-20mA
(Load Resistor<500ohm) |
RS485
Modbus-RTU |
Power Supply | 3.9-30V/DC | 12-30V/DC | 3.9-30V/DC |
Power Consumption | 10mA@24V DC | 30mA@24V DC
(with 20mA output signal) |
10mA@24V DC |
ORP Measurement | Range:+/-2000mV,Resolution:1mV,Accuracy:±2% | ||
IP Ratings | Electrode:IP68
Transmitter:IP65 |
||
Operating Temperature | -40~85℃ | ||
Installation | Electrode:3/4″NPT screw threads
Transmitter:Mounting hole |
||
Cable Length | Power and Signal Cable:2 meters or Customize
Electrode Cable:5 meters |
||
Dimension | Electrode:3/4″NPT screw threads
Transmitter:128*70*42mm |
Parameters | Code | Comments |
Code 1:
Product Series |
ORP10 | ORP10 transmitter |
Code 2:
Power Supply |
A
B |
3.9-30V DC
3.3-16V |
Code 3:
ORP Range |
A
B C |
+/-2000mV
+/-1000mV Customize |
Code 4:
Output Interface |
A
B C D E F G |
Analog Voltage 0-2V
Analog Current 4-20mA RS485,Modbus-RTU RS485,Modbus-RTU & Analog Voltage 0-2V RS485,Modbus-RTU & Analog Current 4-20mA SDI-12 Customize |
Code 5:
Cable Length |
002
XXX |
Electrode Cable:5 meters , Power and Signal Cable:2 meters
Electrode Cable:5 meters , Power and Signal Cable:xxx meters |
Ordering Code Example:
ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005 |
- [Resource] PYR20 Solar Radiation/Pyranomet...
- [Resource] DigiGas-CD Carbon Dioxide CO2 S...
- Resource-CD10 CO2 Transmitter with RS485 M...
- PH10-Non-Isolated PH Transmitter, RS485, M...
- [Resource] DigiLTN-Lightning Sensor, SDI12...
- PHORP10 Isolated PH/ORP Transmitter with R...
- DigiGas-CD Carbon Dioxide CO2 Sensor, SDI1...
- PYR20-Solar Radiation/Pyranometer Sensor, ...